String Single Phase Series
The Highest Efficiency is 97.5%
2 MPPT
RS232/RS485 Interface
IP65 Ingress Protection
High Surge Endurance
High Power Factor
Remote Upgrade Software/ Set Parameters
APP Monitoring Power Station
Fault Diagnosis
Max.DC Input Power/kW | 6.5 | Max.DC Input Voltage/V | 500 |
Star-Up DC Input Voltage/V | 120 | MPPT Voltage Range/V | 100-500 |
Max.DC Input Current/A | 13+13 | Number of MPPT/String Per MPPT | 2/1 |
Max.DC Input Power/kW | 6.5 |
Max.DC Input Voltage/V | 500 |
Star-Up DC Input Voltage/V | 120 |
MPPT Voltage Range/V | 100-500 |
Max.DC Input Current/A | 13+13 |
Number of MPPT/String Per MPPT | 2/1 |
Rated Output Power/kW | 5 | Max. Active Power/kW | 5.5 |
Rated AC Grid Voltage/V | 230 | AC Grid Voltage Rang/V | 180-300 |
Rated Grid Voltage Frequency/Hz | 50/60(optional) | Operating Phase | Single phase |
Rated AC Grid Output Current/A | 22 | Max.AC Output Current/A | 24 |
Output Power Factor | 0.8leading-0.8lagging | Grid Current THD | <3% |
DC Injection Current /mA | <0.5% | Grid Voltage Range | 47-52/57-62(optional) |
Rated Output Power/kW | 5 |
Max. Active Power/kW | 5.5 |
Rated AC Grid Voltage/V | 230 |
AC Grid Voltage Rang/V | 180-300 |
Rated Grid Voltage Frequency/Hz | 50/60(optional) |
Operating Phase | Single phase |
Rated AC Grid Output Current/A | 22 |
Max.AC Output Current/A | 24 |
Output Power Factor | 0.8leading-0.8lagging |
Grid Current THD | <3% |
DC Injection Current /mA | <0.5% |
Grid Voltage Range | 47-52/57-62(optional) |
Max. Efficiency | 0.975 | Euro Efficiency | 0.973 |
MPPT Efficiency | >99% |
Max. Efficiency | 0.975 |
Euro Efficiency | 0.973 |
MPPT Efficiency | >99% |
Anti-Islanding Protection | Integrated | DC Reverse-Polarity Protection | Integrated |
DC Surge Protection | Integrated(Type II) | AC Surge Protection | Integrated(Type II) |
AC Short Circuit Protection | Integrated | AC Output Overcurrent Protection | Integrated |
Output Overvoltage Protection | Integrated | AC Grid Monitoring | Integrated |
Ground Fault Monitoring | Integrated | Insulation Resistance Protection | Integrated |
Residual Current Monitoring Unit | Integrated | Temperature Protection | Integrated |
Integrated DC Switch | Optional |
Anti-Islanding Protection | Integrated |
DC Reverse-Polarity Protection | Integrated |
DC Surge Protection | Integrated(Type II) |
AC Surge Protection | Integrated(Type II) |
AC Short Circuit Protection | Integrated |
AC Output Overcurrent Protection | Integrated |
Output Overvoltage Protection | Integrated |
AC Grid Monitoring | Integrated |
Ground Fault Monitoring | Integrated |
Insulation Resistance Protection | Integrated |
Residual Current Monitoring Unit | Integrated |
Temperature Protection | Integrated |
Integrated DC Switch | Optional |
Size/mm | 330W*310H*172D | Weight/kg | 11 |
Topology | Transformerless | Internal Consumption | <1W(night) |
Running Temperature | -25~+60℃ | Ingress Protection | IP65 |
Noise Emission | <30dB | Cooling Concept | Intelligent cooling |
Max. Operating Altitude Without Derating | 2000m | Designed Lifetime | >20years |
Operating Surroundings Humidity | 0-100% |
Size/mm | 330W*310H*172D |
Weight/kg | 11 |
Topology | Transformerless |
Internal Consumption | <1W(night) |
Running Temperature | -25~+60℃ |
Ingress Protection | IP65 |
Noise Emission | <30dB |
Cooling Concept | Intelligent cooling |
Max. Operating Altitude Without Derating | 2000m |
Designed Lifetime | >20years |
Operating Surroundings Humidity | 0-100% |
DC Connection | MC4 mateable connector | AC Connection | IP65 rated plug |
Display | LCD1602 | Interface | RS485/RS232 |
DC Connection | MC4 mateable connector |
AC Connection | IP65 rated plug |
Display | LCD1602 |
Interface | RS485/RS232 |